Comparison of Clinical Outcomes in Implantable Collamer Lens Implantation between AQUA ICL(R) and Conventional ICL.
Gi Sung Son, Jae Woo Kim, Tae Hyung Lim, Kee Yong Choi, Beom Jin Cho
HanGil Eye Hospital, Incheon, Korea. chobj@empal.com
광학부 중앙원공이 있는 새로운 안내렌즈와 기존 안내렌즈의 임상결과 비교
손지성⋅김재우⋅임태형⋅최기용⋅조범진
한길안과병원
Received: 6 February 2015   • Revised: 19 March 2015   • Accepted: 10 July 2015
Abstract
PURPOSE
To compare the clinical outcomes between AQUA ICL(R) (V4C) and conventional implantable collamer lens (ICL, V4B) in patients with high myopia. METHODS: We compared preoperative and postoperative visual acuities, spherical equivalent, intraocular pressure, postoperative vault and visual quality assessed using optical quality analyzing system (OQAS(R)) between 20 eyes implanted with ICL (V4B) and 22 eyes implanted with AQUA ICL(R) (V4C). RESULTS: Visual acuity (log MAR) and spherical equivalent at postoperative 3 months were 0.06 +/- 0.09 and -0.26 +/- 0.17 D in the V4B group and 0.03 +/- 0.03 and -0.23 +/- 0.19 D in the V4C group, respectively. There was no statistical difference in visual acuity and spherical equivalent between the 2 groups (p > 0.05). Postoperative intraocular pressure (IOP) elevated significantly in both groups until 6 hours after the operation (p < 0.05) compared with preoperative IOP. No significant IOP elevation was observed from the first postoperative day to postoperative 3 months (p > 0.05). V4C resulted in lower IOP than V4B 6 hours postoperatively. In ICL (V4B) and AQUA ICL(R) (V4C) groups, the objective scattering index (OSI) was 1.29 +/- 0.90 and 1.36 +/- 0.68, modulation transfer function (MTF) cut off value was 29.62 +/- 11.31 c/deg and 29.61 +/- 9.56 c/deg and Sterhl ratio was 0.18 +/- 0.07 and 0.17 +/- 0.04, respectively, 3 months postoperatively. None of these values were significantly different between the 2 groups. CONCLUSIONS: AQUA ICL(R) (V4C) implantation is an effective, convenient and safe surgery for myopia correction and yields better outcome than ICL (V4B) in terms of early postoperative IOP.
Key Words: AQUA ICL;Conventional ICL;Implantable collamer lens;Intraocular pressure


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next