Journal of the Korean Ophthalmological Society 1986;27(3):351-361.
Published online March 1, 1986.
Changes in the Rate of Flow by Quantitative Analysis of Aqueous Humor after Argon Laser Trabeculoplasty in Rabbits.
Hyung Woo Kwak, Sang Min Kim
Department of Ophthalmology, School of Medicine, Kyung Hee University, Korea.
가토에서 Argon Laser Trabeculoplasty 시행후 방수의 정량분석에 의한 Flow Rate 의 변화
김상민(Sang Min Kim),곽형우(Hyung Woo Kwak)
Abstract
The measurement of the rate of flow of aqueous humor is very important for the investigation of the physiology in the aqueous humor and maintenance of the intraocular pressure. Argon laser trabeculoplasty apears to be effective in lowering intraocular pressure with much advantage over standard filtering operation but despite the, widespread use of argon laser traheculoplasty in medically unresponsive open angle glaucoma, the exact mechanism by which it reduce outflow resistance remains unknown and so the study of the mechanism and the most suitable site are required due to the associated complication and less effectiveness during long term evaluation. We studied the changes in the rate of constant, the rate of flow for 2 weeks, intraocular pressure and C-value for 4 weeks, histopathologic changes for 36 days after argon laser trabeculoplasty in 25 rabbits(21 white and 4 black). The normal control group of 20 rabbits was also measured for intraocular pressure and C-value and the rate of constant, the rate of flow. In trabeculoplasty, we used the Britt 900 argon laser photocoagulator(pulse wave) with 50~60 burns at a setting of 700~800 mW, 0.2 seconds duration, 50 micro beam diameter in 360 degrees portion at the site between scleral spur and trabecularmeshwork. The results were as follows; 1) In control group of 20 rabbits. 1. The mean normal intraocular pressure was 18.5 +/- 2.0mmHg. 2. The mean normal C-value was 0.385 +/- 0.072 cumm/min/mmHg. 3. The mean normal rate of constant was 0.0114 +/- 0.0021min(-1). 4. The mean normal rate of flow was 3.980 +/- 0.735 micro l/min. 5. The relationship between rate of flow and C-value was high. 2) In rabbits after argon laser trabeculoplasty. 1. The white and black rabbits showed a statistically significant decrease of intraocular pressure for 4 weeks and elevation of rate of flow for 2 weeks after argon laser trabeculoplasty (p<0.001). 2. The changes of post-laser intraocular pressure was related with changes of C-value after argon laser trabeculoplasty for 4 weeks. 3. The changes of the mean IOP and C-value for post-laser 4 weeks showed no significant differences between white group and black group. 4. In histopathologic changes for 36 days, inflammtory change was not seen for post-laser period, fibrosis and edema in trabecular meshwork was more prominent at the 8th day, edema and fibrosis was regressed as normal at the post-laser 27th day.


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next