J Korean Ophthalmol Soc > Volume 60(4); 2019 > Article
Journal of the Korean Ophthalmological Society 2019;60(4):308-314.
DOI: https://doi.org/10.3341/jkos.2019.60.4.308    Published online April 15, 2019.
The Preference of Lid Height and Laterality with an Ocular Prosthesis in Korean Patients.
Hyun Uk Shin, Long Yu Jin, Ji Young Suh, Hee Bae Ahn
Department of Ophthalmology, Dong-A University College of Medicine, Busan, Korea. hbahn@dau.ac.kr
한국인에서 의안착용 후 선호하는 의안의 방향과 눈꺼풀의 높이
신현욱⋅김용욱⋅서지영⋅안희배
동아대학교 의과대학 안과학교실
Correspondence:  Hee Bae Ahn,
Email: hbahn@dau.ac.kr
Received: 25 January 2018   • Revised: 23 March 2018   • Accepted: 23 March 2019
Abstract
PURPOSE
To evaluate the preferred eyelid height and laterality according to differences in marginal reflex distance 1 (MRD1) in Korean patients with an ocular prosthesis. METHODS: A study of 46 eyes was conducted for patients with an ocular prosthesis between August 2016 and March 2018. In a slide show with the original and mirror-reversed photographs and upper eyelid height 1 mm above and below the base level, patients were asked which of the photographs of themselves they preferred. RESULTS: Patients divided evenly into 23 individuals with a right side ocular prosthesis and 23 individuals with a left side ocular prosthesis. Among the patients, 47.8% preferred the mirror-reversed photograph and 52.2% preferred the original photograph. Meanwhile, 67.4% with the left side ocular prosthesis preferred the original photograph and 32.6% with the right side ocular prosthesis preferred the original photograph (p = 0.02). Additionally, 69.3% preferred their upper eyelid height 1 mm above the original photograph, 21.7% preferred their upper eyelid height 1 mm below the original photograph, and 13.0% preferred the level of the original photograph (p < 0.01). Twenty-five patients had < 1 mm difference of MRD1 (group A). Sixteen patients had 1 mm smaller MRD1 with an ocular prosthesis than with a normal eye (group B). Five patients had 1 mm larger MRD1 with an ocular prosthesis than with a normal eye (group C). Group A and B patients preferred the photograph with their upper eyelid 1 mm above from the original photograph (p < 0.01). CONCLUSIONS: Patients with an ocular prosthesis significantly preferred the photograph of their upper eyelid height 1 mm above the base level when the height of the ocular prosthesis was smaller or similar to the normal eye. And patients preferred the photographs with left sided prosthesis regardless of their original direction.
Key Words: Eyelid height and laterality;Mirror-reversed photograph;Ocular prosthesis;Quality of life


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next