The Effectiveness of Visual Field C10-2 in the Early Detection of Glaucoma with Parafoveal Scotoma.
Bo Een Hwang, Hae Young Lopilly Park, Chan Kee Park
Department of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea. lopilly@hanmail.net
중심부 시야결손을 보이는 초기 녹내장 환자의 진단에서 자동시야계 C10-2의 유용성
황보인⋅박혜영⋅박찬기
가톨릭대학교 의과대학 서울성모병원 안과학교실
Correspondence:  Hae-Young Lopilly Park, MD, PhD
Email: lopilly@hanmail.net
Received: 24 November 2016   • Revised: 4 January 2017   • Accepted: 27 February 2017
Abstract
PURPOSE
To identify the correspondence between the central sensitivity of several visual field (VF) tests and ganglion cell inner plexiform layer (GC-IPL) thickness in early glaucoma patients with parafoveal scotoma. METHODS: Fifty-seven eyes from 57 patients with glaucomatous optic neuropathy and parafoveal scotoma were analyzed using the standard automated perimetry (SAP) C10-2 test, the SAP C24-2 test, and the frequency doubling technology perimetry (FDT) C24-2 test. The correlation between the VF central sensitivity and the GC-IPL thickness from macular scans via optical coherence tomography was analyzed. RESULTS: The central sensitivity was 27.51 ± 5.43 dB, 27.39 ± 5.05 dB, and 22.09 ± 5.08 dB for SAP C24-2, SAP C10-2, and FDT C24-2, respectively. Mean GC-IPL thickness was 70.2 ± 8.5 µm. Using regression analysis, the value of log R² between the logarithmic central sensitivity and GC-IPL thickness was 0.498, and the linear R2 between the antilogarithmic central sensitivity and GC-IPL thickness in SAP C10-2 was 0.486, and both were statistically significant (p < 0.05). This relationship was stronger in early glaucoma patients compared to late glaucoma patients using SAP C10-2. CONCLUSIONS: The structure-function relationship between GC-IPL thickness and central sensitivity was better with SAP C10-2, especially in early glaucoma patients, compared to other VF modalities.
Key Words: C10-2;Early glaucoma;Optical coherence tomography;Parafoveal scotoma;Structure-function analysis


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next