J Korean Ophthalmol Soc > Volume 55(11); 2014 > Article
Journal of the Korean Ophthalmological Society 2014;55(11):1693-1697.
DOI: https://doi.org/10.3341/jkos.2014.55.11.1693    Published online November 15, 2014.
Result of Visual Evoked Potential, Electroretinography and Electrooculography in Normal Subjects Using MonPack 3 System.
Seong Gyu Min, Young Hoon Lee, Sun Young Jin
Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea. jin-sy@hanmail.net
Mon–Pack 3로 측정한 정상인의 전기 생리학적 검사 결과
민성규⋅이영훈⋅진선영
Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
Abstract
PURPOSE
We present the results of visual evoked potential (VEP), electroretinography (ERG), and electrooculography (EOG) in normal subjects using the Mon-pack 3 system (Metrovision). METHODS: VEP, ERG, and EOG were obtained in 92 normal eyes. The measurements followed the International Society for Clinical Electrophysiology of Vision (ISCEV) standardization protocol. In VEP, the standard electrode was placed on the forehead and the active electrode was attached on the occiput. In ERG, a 20-minute dark adaptation was performed after mydriasis, and an ERG-jet electrode was used. EOG was measured by attaching an electrode to each medial canthal skin. Each latent period and electric potential was measured with average, standard deviation, median, and 95% confidencenterval (95% CI). RESULTS: The mean P100 latency in pattern VEP was 104.36 ms, and P100 latency in flash VEP was 116.71 ms. For the maximal ERG response, the implicit times of a and b waves were 22.65 ms and 44.58 ms, respectively and the amplitude of a and b waves were 274.09 microv and 489.52 microv, respectively. For the ERG cone response, the implicit time of a and b waves were 18.21 ms and 33.40 ms, respectively, and the amplitude of a and b waves were 35.87 microv and 104.42 microv, respectively. The mean ERG oscillitatory potential was 285.53 microv. The average EOG Arden ratio was 2.54. CONCLUSIONS: VEP, ERG, and EOG results from normal subjects using the Mon-pack 3 system can be applied to the diagnosis of retina and optic nerve disease and basic research.
Key Words: Electrooculography;Electroretinography;Mon-pack 3 system (Metrovision);Normal subjects;Visual evoked potential


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next