J Korean Ophthalmol Soc > Volume 56(6); 2015 > Article
Journal of the Korean Ophthalmological Society 2015;56(6):875-884.
DOI: https://doi.org/10.3341/jkos.2015.56.6.875    Published online June 15, 2015.
Comparison of Clinical Outcomes between Diffractive and Refractive Multifocal Intraocular Lens with Same Near Added.
Jee Hyun Kim, Eun Joo Kim, Yong Il Kim, Gwang Ja Lee, Kyoo Won Lee, Young Jeung Park
Cheil Eye Hospital, Daegu, Korea. eyepark9@naver.com
덧댐굴절력이 같은 회절성과 굴절성 다초점 인공수정체의 임상 결과 비교
김지현⋅김은주⋅김용일⋅이광자⋅이규원⋅박영정
제일안과병원
Received: 27 September 2014   • Revised: 15 January 2015   • Accepted: 12 May 2015
Abstract
PURPOSE
To compare the clinical outcomes between refractive-type multifocal intraocular lenses (IOL) (Lentis Mplus(R) LS 313, Oculentis GmbH., Berlin, Germany) and diffractive-type multifocal IOL (Acrysof Restor(R); SN6AD1, Alcon Lab., Fort Worth, TX, USA) with same near added. METHODS: We evaluated 30 eyes implanted with Lentis Mplus(R) IOL and 33 eyes implanted with Acrysof Restor(R) IOL after phacoemulsification. The distant, intermediate, and near uncorrected visual acuities of the 2 groups were evaluated at 2 weeks and 1, 3, and 6 months postoperatively. Optical quality obtained using the Optical Quality Analysis System II (OQAS II(R), Visiometrics, Castelldefels, Barcelona, Spain), higher-order aberrations (HOAs), and patient satisfaction questionnaire of the 2 groups were evaluated at 3 months postoperatively. RESULTS: The visual acuity of intermediate 100 cm was statistically better in the Lentis Mplus(R) group (p < 0.05). There were no significant differences between the 2 groups with distant, intermediate 63 cm, and near vision. At the 3-month postoperative follow-up, objective scatter index, modulation transfer function (MTF) cutoff value, and pseudo-accommodation range measured by OQAS II(R) showed no differences between the 2 groups, but Strhel ratio was higher in the Acrysof Restor(R) group. HOAs of 5 mm and 6 mm increased significantly in the Lentis Mplus(R) group. No significant differences were found in the patient satisfaction questionnaire. CONCLUSIONS: Both refractive and diffractive-type multifocal IOL implantation in patients with cataracts and presbyopia offered good and comparable visual acuity at distance and near. However, the Lentis Mplus(R) IOL provided better intermediate vision than the Acrysof Restor(R) IOL.
Key Words: Cataract;Diffractive;Multifocal intraocular lens;Presbyopia;Refractive


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next