Comparison of Anterior Chamber Parameter and Refractive Change between Three-Piece and Single-Piece Aspheric Intraocular Lenses.
Hye Sun Kim, Dong Min Lee, Ji Min Ahn, Eung Kweon Kim, Tae Im Kim
1Department of Ophthalmology, Yonsei University College of Medicine, The Institute of Vision Research, Seoul, Korea. taeimkim@gmail.com
2Siloam Eye Hospital, Seoul, Korea.
삼체형과 일체형 비구면 인공수정체 삽입 후 전방부 계측치와 굴절력의 비교
김혜선1⋅이동민1⋅안지민2⋅김응권1⋅김태임1
Department of Ophthalmology, Yonsei University College of Medicine, The Institute of Vision Research1, Seoul, Korea
Siloam Eye Hospital2, Seoul, Korea
Abstract
PURPOSE
To compare the anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA) and refractive change after cataract surgery between 3-piece and 1-piece aspheric intraocular lens (IOL) implantation. METHODS: The present study consisted of 16 patients (25 eyes) having 3-piece aspheric Tecnis(R) ZA9003 IOL and 21 patients (30 eyes) having 1-piece aspheric Tecnis(R) ZCB00 IOL. The ACD, ACV, and ACA were measured using an anterior eye segment analysis system (Pentacam, Oculus, Wetzlar, Germany) preoperatively and postoperatively 1 week and 1 month. Refractive outcomes were evaluated using an autokeratometer. RESULTS: When comparing the 3-piece (Tecnis(R) ZA9003) and 1-piece (Tecnis(R) ZCB00) IOL with the same optic, ACD, ACV, and AVA increased significantly after cataract surgery. The 1-piece IOL showed deeper ACD than the 3-piece IOL at postoperative 1 week and 1 month. Postoperative refraction showed slight myopic shift compared with target diopter, but was stable in both groups. CONCLUSIONS: There was significant increase in ACD, ACV, and ACA after cataract surgery in both IOL-inserted groups. Results showed stable refraction after cataract surgery in both groups. Consideration of the A-constant will be needed because of myopic change with the 1-piece IOL.
Key Words: Anterior chamber depth;Aspheric IOL;Refraction;Tecnis(R) ZA9003;Tecnis(R) ZCB00


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next