Clinical Outcome of in-the-Bag Single-Piece Aspheric Intraocular Lens Implantation after Microincision Cataract Surgery.
Yoon Jeon Kim, Mi Hyun Cheon, Dong Ah Ko, Jae Yong Kim, Myoung Joon Kim, Hung Won Tchah
Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. hwtchah@amc.seoul.kr
미세각막절개 백내장 수술 후 낭내 삽입한 일체형 비구면 인공수정체의 임상 결과
김윤전⋅전미현⋅고동아⋅김재용⋅김명준⋅차흥원
Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
Abstract
PURPOSE
To evaluate the stability and optical performance of the newly developed single-piece aspheric intraocular lens (IOL) by comparing the clinical outcome of the aspheric IOL with the new optic profile design (HOYA iSert, HOYA iMics) and the aspheric IOL (Akreos MI60), which has been proven effective and safe. METHODS: iSert, iMics, and MI60 were inserted into 55 eyes, 60 eyes, and 50 eyes, respectively, after microincision phacoemulsification cataract surgery. Best corrected visual acuity (BCVA), refraction in spherical equivalent, anterior chamber depth (ACD), total higher order aberration (HOA), contrast sensitivity, and surgically induced astigmatism (SIA) were measured and each IOL was evaluated on the functional stability, anterior-posterior stability, centration in the capsular bag, and quality of vision. RESULTS: No statistical differences in preoperative and postoperative BCVA among the 3 IOL groups were observed, however, MI60 showed significant myopic shift postoperatively. Anterior-posterior stability assessed with postoperative change in refractive error and ACD was slightly lower in the MI60 group. In terms of vision quality, while total aberration, total HOA, coma aberration, and contrast sensitivity for the 3 IOLs were not different significantly, spherical aberration of the MI60 group was higher than the other groups at 6 months postoperative. SIA was significantly increased in eyes implanted with iSert than in eyes with iMics or MI60 at 1 month postoperatively, however, the differences were no longer evident after 3 months postoperatively. CONCLUSIONS: The new aspheric IOLs, iSert and iMics, showed good stability and visual outcome equal to MI60 at the 6-month postoperative follow-up.
Key Words: Anterior-posterior stability;Aspheric intraocular lens;Contrast sensitivity;Microincision phacoemulsification cataract surgery;Spherical aberration


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next