Changes in Optical Quality of Cataract Patients' Corrected Visual Acuity before and after Phacoemulsification.
Chang Won Park, Yong Eun Lee, Choun Ki Joo
Department of Ophthalmology and Institute for Visual Science College of Medicine, The Catholic University of Korea, Seoul, Korea. ckjoo@catholic.ac.kr
백내장 수술 전후 교정시력의 변화가 없는 환자 군에서 OQAS를 이용하여 측정한 광학적 질의 변화
박창원⋅이용은⋅주천기
Department of Ophthalmology and Institute for Visual Science College of Medicine, The Catholic University of Korea, Seoul, Korea
Abstract
PURPOSE
To evaluate objectively the improvement level of a patient's visual function using the NEI-VFQ-25 questionnaire pre- and post-operatively and the OQAS results from the patient group who had the same corrected visual acuity pre- and post-operatively. METHODS: We examined and compared the NEI-VFQ-25 test, OSI, MTF cut-off, strehl ratio, OQAS, and width at 50% and 10% in 24 eyes of 24 patients who had cataract surgery between December 2011 and February 2012. The patients' corrected visual acuity in both eyes had no change (0.8 and 0.8) pre-operatively and 2 months post-operatively (1.0 and 1.0). RESULTS: The satisfaction level regarding the patients' visual function increased. The NEI-VFQ-25 test was 71.54 +/- 14.88 points pre-operatively and 85.70 +/- 6.17 points post-operatively. OSI decreased to 3.13 +/- 1.66 (OSI value) and 1.53 +/- 0.58 (OSI value), and MTF cut off value improved from 14.51 +/- 6.97 (C/deg) to 27.63 +/- 8.98 (C/deg). Strehl ratio was improved to 0.09 +/- 0.03 and 0.14 +/- 0.03, width at 50% improved to 8.44 +/- 3.73 and 4.52 +/- 1.90 and width at 10% improved to 35.30 +/- 15.22 and 18.04 +/- 8.87 pre- and post-operatively, respectively. CONCLUSIONS: The NEI-VFQ-25 test reflected the vision improvement in patients where after cataract surgery, determination of the visual function improvement only through vision would not be possible. In addition, the OQAS showed the quality of vision improved through quantified values.
Key Words: Cataract surgery;MTF;NEI-VFQ-25;OQAS;OSI


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next