J Korean Ophthalmol Soc > Volume 54(9); 2013 > Article
Journal of the Korean Ophthalmological Society 2013;54(9):1353-1358.
DOI: https://doi.org/10.3341/jkos.2013.54.9.1353    Published online September 15, 2013.
Comparison of Surgical Parameters and Outcomes According to the Phacoemulsification Technique.
Soa Kim, Dong Ah Ko, Jae Yong Kim, Myoung Joon Kim, Hung Won Tchah
Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. hwtchah@amc.seoul.kr
초음파유화술의 방법에 따른 수술과정 및 결과의 차이
김소아⋅고동아⋅김재용⋅김명준⋅차흥원
Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
Abstract
PURPOSE
To compare intraoperative parameters and postoperative results between divide-and-conquer and multiple phaco-chop technique. METHODS: Two different techniques were performed by one operator on the patients with bilateral cataract. One eye was phacoemulsified by divide-and-conquer technique (D eye), and the other was performed by multiple phaco-chop technique (M eye). Changes of central corneal thickness during the operation, total phaco-time and phaco-energy were measured. RESULTS: Total 29 patients were included. The change of central corneal thickness were 8.4 +/- 11.8 microm in D eye and 11.5 +/- 16.7 microm in M eye, which showed no significant difference (p = 0.350) and total phaco-time were 70.1 +/- 32.9 seconds in D eye and 71.1 +/- 55.0 seconds in M eye, which also showed no significant difference (p = 0.689). However, phaco-energy were 12.4 +/- 8.3 power x s in D eye and 8.4 +/- 9.9 power x s in M eye, and this result showed significantly larger energy when using divide-and-conquer technique (p < 0.001). CONCLUSIONS: There was no significant difference in change of central corneal thickness and phaco-time between two techniques, divide-and-conquer and multiple phaco-chop technique. However, significantly smaller phaco energy was used by multiple phaco-chop technique compared with divide-and-conquer technique.
Key Words: Cataract surgery;Divide and conquer;Multiple phaco-chop;Phacoemulsification;Phaco energy


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next