Journal of the Korean Ophthalmological Society 2006;47(10):1561-1567.
Published online October 31, 2006.
Comparision of the Three Different Hydrophilic Acrylic Intraocular Lenses.
Suk Ho Byeun, Wan Soo Kim
1Department of Ophthalmology, Maryknoll Hospital, Korea. wansookim@yahoo.com
2Department of Ophthalmology, Pusan St. Mary's Hospitall, Pusan, Korea.
3가지 친수성 아크릴 인공수정체의 안정성 비교
변석호1,김완수1,2
Department of Ophthalmology, Maryknoll Hospital1 and Pusan St. Mary`s Hospitall2, Pusan, Korea
Correspondence:  Suk Ho Byeun, M.D.1
Abstract
PURPOSE
To evaluate the stability of three different hydrophilic acrylic intraocular lenses (IOLs), which have different shapes. IOLs included in this study are three-piece acrylic IOL with PMMA (Polymethylmethacrylate) haptics (Hydroview(R) H60M, Bausch &Lomb, U.S.A), one-piece acrylic IOL with broad optic-haptic junction (Centerflex(R) 570H, RAYNER, UK), and one-piece acrylic IOL with narrow optic-haptic junction (Aquasens, Ophthalmic Innovations International, U.S.A). METHODS: We evaluated 69 patients (100 eyes) who had undergone cataract surgeries and who had hydrophilic acrylic IOLs implanted from September, 2003 to March, 2004. Forty eyes implanted with three-piece acrylic IOL with PMMA haptics, 40 eyes implanted with one-piece acrylic IOL with broad optic-haptic junction, and 20 eyes implanted with one-piece acrylic IOL with narrow optic-haptic junction were included. Slit lamp examination, best corrected visual acuity (BCVA), anterior chamber depth (ACD), refraction, and IOL decentration were evaluated at one week and at one, three, and six months postoperatively. RESULTS: There was no statistically significant difference in BCVA, ACD, mean SE or decentration between patients implanted with three different types of hydrophilic acrylic IOL during the 6 month follow-up period (P>0.05). However, Postoperative myopic shift was discovered in 4 eyes (4/20) with Aquasens. CONCLUSIONS: There were no statistically significant difference in the Stabilities of the 3-different hydrophilic acrylic IOLs. However, patients who were implanted Aquasens shold be observed carefully because Aquasense has the posibilitiy to have myopic shift more than 1 Dioptor.
Key Words: Hydrophilic acrylic intraocular lens;Myopic shift


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next