Journal of the Korean Ophthalmological Society 1974;15(1):9-15.
Published online January 1, 1974.
Experimental Studies on the Sterilization of The Soft Contact Lens.
San Bae Kim
Department of Ophthalmology, College of Medicine, Seoul National University, Seoul, Korea.
연성 (軟性) 콘택트렌즈의 멸균에 대한 실험적 연구
김산배 ( San Bae Kim )
Abstract
Mycon-soft lenses (made by Tokyo contact lens Co., Japan) were contaminated experimentally with coagulase positive staphylococcus aureus and pseudomonas aeruginosa and sterilizing effects of some disinfectants (3% H2O2, 6% H2O2, 0.1% Benzalkonium and 1:1000 Merthiolate solutions) on those contaminated lenses were studied. The following results were obtained: 1. SCL contaminated with staphylcoccus were sterilized by soaking in 3% H2O2, 6% H2O2, or 1:1000 Merthiolate solution over 15 minutes, and in 0.1 Benzalkonium over 60 minutes. 2. SCL contaminated with pseudomonas aeruginosa were sterilizd by soaking in 6% H2O2 over 15 minutes, in 1:1000 MerthioJate solution over 60 minutes, in 3% H2O2 over 60 minutes, but no sterilization was obtained by soaking in 0.1 % Benzalkonium solution for less than 180 minutes. 3. No signs of irritation were noted on rabbit corneas fitted with SCL after soaking in 3% H2O2 or 6% H2O2 for 15 minutes followed by soaking in 20cc of normal saline for 15 minutes.


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next