The Flash Light Emitted Diode Flash Visual Evoked Potential(Flash VEP) is useful when patients are unable to cooperate sufficiently for a Pattern Reversal Visual Evoked Potential(RP-VEP). In order to evaluate the clinical utility of Flash VEP, we performed the PR-VEP and Flash VEP in 208 eyes of 104 normal persons. The average P100 latency(LaP100) was analyzed according to check size, age, sex, and the laterality of the eye. The LaP100 of PR-VEP stimulated with 8 X 8(120' X 96'), 16 X 16(60' X 48'), 32 X 32 (30' X 24') and 64 X 64(15' X 12') check size were 98.88 +/- 7.57msec(mean S.D msec) , 97.68 +/- 7.44msec, 96.31 +/- 7.21msec, 101.20 +/- 7.81msec, respectively. The LaP100 of PR-VEP stimulated with 32 X 32 check size at 3rd, 4th, 5th, 6th and 7th decades were 93.95 +/- 5.61msec, 94.70 +/- 7.71msec, 92.92 +/- 6.28msec, 97.78 +/- 6.24 msec, 102.79 +/- 5.27msec, respectively. The LaP100 of PR-VEP remained relatively stable until over 6th decade when it increased significantly (p<0.05). The LaP100 of FlashVEP in age of 3rd, 4th, 5th, 6th and 7th decade were 87.08 +/- 7.82msec, 91.07 +/- 8.46msec, 99.37 +/- 6.36msec, 105.30 +/- 7.82msec, and 111.62 +/- 5.54msec, respectively. The LaP100 of Flash YEP increased progressively with aging changes(p<0.05). There were no statistically significant differences between the left and right eyes(p>0.05), and between male and female(p>0.05) in the LaP100 of both VEP. These results showed that LaP100 of PR-VEP changes according to the check size and patient's age. We should interprete the LaP100 of PR-VEP or Flash VEP after the processing of averaging its P100 according to the patient's.
Key Words: Aging change;Average P100 latency(LaP100);Check size;Flash VEP;PR-VEP
TOOLS
METRICS Graph View
  • 519 View
  • 22 Download
Related articles


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next