Abstract
We measured the lens thickness and anterior chamber depth on 214 eyes (162 cataract eyes, 52 normal control eyes) using the EAS-1000 Scheimpflug camera. And the results was compared with measurement of A-scan ultrasonography in 49 cataract eyes. The thickness of cataract lens, especially in anterior subcapsular opacities in over 61 years old was significantly thin rather than control lens (p0.05). Lens thickness was increased with age by an annual rate of 0.0l5mm in monnal eyes (p
Key Words: Anterior chamber depth;A-scan ultrasonography;EAS-1000 Scheimpflug camera;Lens thickness