Effects of Anterior Chamber Depth and Axial Length on Refractive Error after Intraocular Lens Implantation.
Hyo Sung Maeng, Eun Hye Ryu, Tae Young Chung, Eui Sang Chung
J Korean Ophthalmol Soc. 2010;51(2):195-202.   Published online 2010 Feb 15     DOI: https://doi.org/10.3341/jkos.2010.51.2.195
Citations to this article as recorded by Crossref logo
Comparison of Intraocular Lens Power Formula Accuracy for Flanged Intrascleral Intraocular Lens Fixation
Ji Woong Chun, Young Chang Lee, Deok Bae Kim, Mu Oh Jung
Journal of Retina.2022; 7(1): 43.     CrossRef
Comparison of the Accuracies of Intraocular Lens Power Formulae by the Type of Implanted Lens
Jin Ju Choi, Ha Kyoung Kim, Kayoung Yi
Journal of the Korean Ophthalmological Society.2021; 62(3): 315.     CrossRef
Effects of Axial Length and Anterior Chamber Depth on Intrascleral Fixation Using a Fibrin Adhesive
Hyeon Woo Son, Jung Min Park
Journal of the Korean Ophthalmological Society.2021; 62(5): 656.     CrossRef
Comparison of Three Formulas for Intraocular Lens Power Formula Accuracy
Ki Woong Lee, Jinsoo Kim, Dong Hyun Kim
Journal of the Korean Ophthalmological Society.2020; 61(1): 27.     CrossRef
Comparison of postoperative refractive outcome in eyes undergoing combined phacovitrectomy vs cataract surgery following vitrectomy
Paris G. Tranos, Bruce Allan, Miltiadis Balidis, Athanasios Vakalis, Solon Asteriades, George Anogeianakis, Magda Triantafilla, Nikolaos Kozeis, Panagiotis Stavrakas
Graefe's Archive for Clinical and Experimental Ophthalmology.2020; 258(5): 987.     CrossRef
Anterior chamber indices in a population-based study using the Pentacam
Hassan Hashemi, AbbasAli Yekta, Farzad Khodamoradi, Mohamadreza Aghamirsalim, Amir Asharlous, Mehrdad Assadpour, Mehdi Khabazkhoob
International Ophthalmology.2019; 39(9): 2033.     CrossRef
Refractive Error Induced by Combined Phacotrabeculectomy
Jun Seok Lee, Chong Eun Lee, Ji Hae Park, Sam Seo, Kyoo Won Lee
Journal of the Korean Ophthalmological Society.2018; 59(12): 1173.     CrossRef
Comparison of Refractive Power and Astigmatism between Digital Keratometer and Autorefractor
Jae Won Choi, Sang Youp Han, Kyung Heon Lee
Journal of the Korean Ophthalmological Society.2017; 58(1): 21.     CrossRef
Influence of Biometric Variables on Refractive Outcomes after Cataract Surgery in Angle-closure Glaucoma Patients
Kyoung Nam Kim, Hyung Bin Lim, Jong Joo Lee, Chang-Sik Kim
Korean Journal of Ophthalmology.2016; 30(4): 280.     CrossRef
Comparative Analysis of Corneal Refractive Power Measured with AL-ScanĀ®, Autokeratometer, and PentacamĀ®
Sung Jin Park, Sung Hyup Lim, Ho Young Lee
Journal of the Korean Ophthalmological Society.2014; 55(7): 984.     CrossRef
Accuracy of Intraocular Lens Power Calculations According to Corneal Curvature in Short Eyes
JeongJae Oh, Jin Seok Choi
Journal of the Korean Ophthalmological Society.2014; 55(6): 826.     CrossRef
Analysis of Factors that Influence on Accuracy of Intraocular Lens Power Calculation
Bo Hyuck Kim, Won Ryang Wee, Mee Kum Kim
Journal of the Korean Ophthalmological Society.2014; 55(2): 173.     CrossRef
Formula Comparison for Intraocular Lens Power Calculation Using IOL Master and Ultrasound for the ZCB00 IOL
Dong Hoon Shin, Dong Hui Lim, Ja Young You, Eui Sang Chung, Tae Young Chung
Journal of the Korean Ophthalmological Society.2014; 55(4): 527.     CrossRef
Comparison of the Refractive Outcomes According to the Differences of Biometry and Keratometry Reading
Kang Hoon Lee, Na Rae Kim, Kyoung Yul Seo
Journal of the Korean Ophthalmological Society.2013; 54(9): 1345.     CrossRef
Effects of Axial Length and Vitrectomy on Refractive Error after Cataract Surgery Using SRK/T Formula
Min Kyu Lee, Kyu Yeon Hwang, Man Soo Kim
Journal of the Korean Ophthalmological Society.2013; 54(2): 257.     CrossRef
Refractive Eerror According to the Anterior Chamber Depth and Corneal Refractive Power in Short Eyes
Jeong Ah Shin, Kyu Yeon Hwang, Man Soo Kim
Journal of the Korean Ophthalmological Society.2013; 54(1): 65.     CrossRef
Choice of One-Piece Intraocular Lens Power and Changes of Anterior Chamber in Sulcus Implantation due to Posterior Capsular Rupture during Cataract Surgery
Jong Yun Yang, Kyoung Tak Ma, Ji Hyun Kim
Journal of the Korean Ophthalmological Society.2012; 53(6): 775.     CrossRef
Comparison of Corneal Curvatures Obtained with Different Devices
Soyoon Kim, Sung Kun Chung
Journal of the Korean Ophthalmological Society.2012; 53(5): 618.     CrossRef
Accuracy of the Haigis Formula Based on Axial Length and Anterior Chamber Depth
Chan-Hui Yi, Sung-Ho Choi, Eui-Sang Chung, Tae-Young Chung
Journal of the Korean Ophthalmological Society.2011; 52(2): 175.     CrossRef
Accuracy of Intraocular Lens Power Calculations According to the Formulas and Anterior Chamber Depth in Short Eyes
Young-Eun Lee, Kyu-Ryong Choi, Roo Min Jun
Journal of the Korean Ophthalmological Society.2010; 51(10): 1338.     CrossRef