Ocular Torsion Measured by Fundus Photographs and Optical Coherent Tomography in Normal Koreans.
Si Hyung Lee, So Young Kim
Department of Ophthalmology, Soonchunhyang University Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan, Korea. ophdrkim@schmc.ac.kr
안저사진 및 빛간섭단층촬영으로 측정한 정상 한국인의 회선 상태
이시형⋅김소영
Department of Ophthalmology, Soonchunhyang University Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan, Korea
Abstract
PURPOSE
To investigate the normal range of ocular torsion in Koreans with no ophthalmologic history using fundus photographs and optical coherence tomography and compare the results of the two methods. METHODS: Fundus photographs and optical coherence tomography were conducted in 400 eyes of 200 people with no ophthalmologic history. ImageJ(R) was used to measure the center of the optic nerve head to foveal angle with fundus photographs. For optical coherence tomography, the fovea-to-disc alignment function in the computer program was used to automatically calculate the angle. Then, the calculated angles measured by the two different methods were compared. RESULTS: In fundus photographs, the angle of the fovea from the center of the optic nerve head was 6.26 +/- 2.92 degree in the right eye, 6.65 +/- 2.58 degree in the left eye, and the mean value was 6.47 +/- 2.76 degrees. From the automatic calculation in optical coherence tomography, the angle of the fovea from the center of the optic nerve head was 6.12 +/- 3.00 degree in the right eye, 6.83 +/- 2.70 degree in the left eye, and the mean value was 6.52 +/- 2.83 degrees. There was no statistically significant difference between the results of the two different methods. In addition, no statistically significant difference was observed between the right and left eyes, sexes, or ages. CONCLUSIONS: When comparing the conventional method of measuring ocular torsion with fundus photographs to optical coherent tomography, the fovea-to-disc alignment function of the optical coherent tomography may be useful to automatically calculate the cyclotorsion.
Key Words: Fundus photography;Ocular torsion;Optical coherence tomography


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next