J Korean Ophthalmol Soc > Volume 49(9); 2008 > Article
Journal of the Korean Ophthalmological Society 2008;49(9):1425-1430.
DOI: https://doi.org/10.3341/jkos.2008.49.9.1425    Published online September 15, 2008.
Comparison of the Flap Complication Rate Between Microkeratomes for LASIK.
Jee Yun Ahn, Ji Won Kwon, Sang Mok Lee, Won Ryang Wee, Jin Hak Lee, Young Keun Han
1Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea. eye129@paran.com
2Seoul Artificial Eye Center, Clinical Research Institute, Seoul National University Hospital, Seoul, Korea.
3Seoul National University Hospital, Health Care System Gangnam Center, Healthcare Research Institute, Seoul, Korea.
4Department of Ophthalmology, Seoul National University Boramae Hospital, Seoul, Korea.
5Department of Ophthalmology, Seoul National University Bundang Hospital, Seongnam, Korea.
라식수술에서 미세각막절개도간의 각막절편 합병증 비교
안지윤1,2ㆍ권지원1,2,3ㆍ이상목1,2,4ㆍ위원량1,2ㆍ이진학1,2,5ㆍ한영근1,2,4
Department of Ophthalmology, Seoul National University College of Medicine1, Seoul, Korea / Seoul Artificial Eye Center, Clinical Research Institute, Seoul National University Hospital2, Seoul, Korea / Seoul National University Hospital, Health Care System Gangnam Center, Healthcare Research Institute3, Seoul, Korea / Department of Ophthalmology, Seoul National University Boramae Hospital4, Seoul, Korea / Department of Ophthalmology, Seoul National University Bundang Hospital5, Seongnam, Korea
Abstract
PURPOSE
To compare intraoperative and postoperative flap complication rate between the Hansatome Excellus and Zyoptix XP microkeratomes for LASIK surgery. METHODS: The intra- and post-operative flap complication rate, in 323 eyes of 167 patients operated on using the Hansatome microkeratome were compared with 260 eyes of 132 patients that were operated on using the Zyoptix XP microkeratome. RESULTS: The Hansatome group showed an intraoperative complication incidence of 2.7% compared to 0.4% for the Zyoptix XP group (p<0.05), but the incidence of postoperative complication was 2.7% in the Zyoptix XP group compared to 0.6% in the Hansatome group (p>0.05). There was no incidence of visually significant complications in either group. CONCLUSIONS: The Zyoptix XP showed a significantly decreased intraoperative flap complication rate compared to the Hansatome Excellus microkeratome. The preoperative K value is an important factor for safe LASIK.
Key Words: Flap complication;Hansatome Excellus;LASIK;Microkeratome;Zyoptix XP


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next