Journal of the Korean Ophthalmological Society 2003;44(7):1649-1661.
Published online July 1, 2003.
The Effect of RGP Lens and Reverse Geometry Lens on Apoptosis in Rabbit Cornea.
Dong Bin Shin, Jung Chul Kim, Mee Kum Kim, Kil Whan Ko, Jae Lim Lee, Si Whan Choi
1Department of Ophthalmology, Chungnam National University College of medicine, Daejon, Korea. opht@unitel.co.kr
2Department of Ophthalmology, Seoul National University Hospital, Seoul, Korea.
RGP 렌즈와 역기하렌즈가 가토각막의 세포사에 미치는 영향
신동빈 ( Dong Bin Shin ) , 김정철 ( Jung Chul Kim ) , 김미금 ( Mee Kum Kim ) , 고길환 ( Kil Whan Ko ) , 이재림 ( Jae Lim Lee ) , 최시환 ( Si Whan Choi )
Abstract
PURPOSE
To investigate the cytotoxic effect of rigid gas permeable(RGP) and reverse geometry lens(RGL) on rabbit corneal cells. METHODS: In 36 white rabbits, right eyes were worn with either RGP or RGL. Left eyes were served as control. The rabbits were sacrificed at 1, 3, 7, 14 days after fitting and 7, 14 days after removal. Morphological changes of the basal epithelial cells and stromal keratocytes were observed using the light and transmission electron microscopy. The samples were examined after TUNEL staining in 3 high power fields (x400). RESULTS: In control eyes, 2.26% of central corneal epithelial cells showed apoptosis. After RGP wearing, the epithelial apoptosis decreased by 0.32% compared to control eyes(2.17%) at 14 days(p<0.001), and returned to 1.55% at 14 days after lens removal(2.04% in control, p=0.161). After RGL wearing, the degree of apoptosis was also lower than control(3.22%) by 0.30% at 14 days(p=0.003). However, it increased to 0.75% at 14 days after lens removal(1.67% in control, p=0.077). A few TUNEL positive fibroblasts were found in superficial stroma in both RGP and RGL group, but not in control eyes. CONCLUSIONS: Both RGP and RGL wearing may decrease the degree of apoptosis in corneal epithelium and lead the apoptosis in corneal stroma. The degree of apoptosis was recovered after lens removal, suggesting the process might to be reversible. The fitting with RGL induced apoptosis of keratocyte more than the fitting with RGP did. It suggests that the RGL wearing may be less physiologic than RGP wearing.
Key Words: Apoptosis;Reverse geometry lens;Rigid gas permeable lens;TUNEL stain


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next