Journal of the Korean Ophthalmological Society 1997;38(10):1748-1754.
Published online October 1, 1997.
Reproducibility of the Peripapillary and Retinal Perfusion Measurement with Confocal Scanning Laser Flowmetry.
Dong Soo Kim, Man Sung Song, Kee Yong Choi
Department of Ophthalmology, Incheon Chung-Ang Gil General Hospital, Incheon, Korea.
Confocal scanning laser flowmetry 를 이용한 시신경유두주위와 망막 미세혈류 측정의 재현성
김동수(Dong Soo Kim),송만성(Man Sung Song),최기용(Kee Yong Choi)
Abstract
Confocal scanning laser flowmetry(HRF: Heidelberg Retina Flowmetry) is a new kind of instrument which enables non-invasive two-dimentional mapping of perfusion of the retina and optic disc and to evaluate the clinically available reproducibility of the peripapillary and retinal perfusion measurement with the confocal scanning laser flowmetry, the authors calculate the coefficient of variation (CV) from the parameters(volume, flow, velocity). The authors indicate two region of interest in the peripapillary region and retina, not overlapping the large vessels and measure the parameters three times consecutively(one session) while visiting three times intervalled(three session), thereafter calculate the mean CV of parameters in ten healthy eyes of ten subject. The CV of parameters obtained with the confocal scanning laser flowmetry was low relatively and therefore reproducibility was high as the CV lower, the reproducibility higher. Comparing the CV between one session and three session measurement to know the clinically available measurement frequency, the CV of three session (volume 13%, flow 16.7%, velocity 16%) was lower than the CV of one session (volume 16.7%, flow 20.7%, velocity 20.1%) in the peripapillary region(Students t test; volume p=0.009, flow p=0.03, velocity p=0.016) and the CV of three session (volume 16.7%, flow 20.7%, velocity 17%) was lower than the CV of one session (volume 18.2%, flow 21.8%, velocity 21.7%) in the retina(Students t test; volume p=0.017, flow p=0.0009, velocity p=0.0004). Above the results, the CV of parameters(13~21.8%) in one and three session had relatively high reproducibility. Also the CV between two measurements had a difference statistically but the difference was not so high, the authors concluded the confocal scanning laser flowmetry which have high resolution measure the peripapillary region and retina reproduciblly with only one time visit, three consecutive measurements.
Key Words: Confocal scanning laser flowmetry;Peripapillary;Coefficient of variation;Session;Parameter


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next