J Korean Ophthalmol Soc > Volume 50(9); 2009 > Article
Journal of the Korean Ophthalmological Society 2009;50(9):1289-1294.
DOI: https://doi.org/10.3341/jkos.2009.50.9.1289    Published online September 15, 2009.
Five-year Study of 120 Endoscopic Conjunctivodacryocystorhinostomy Using Porous Polyethylene-Coated Tear Drain.
Il Hun Seo, Tae Soo Lee
Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea. tsoooo@hanmail.net
다공성 폴리에틸렌으로 둘러싼 존스관을 이용한 120예의 결막누낭비강연결술의 5년간의 연구
서일훈ㆍ이태수
Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea
Abstract
PURPOSE
To evaluate the long-term surgical results of 120 endoscopic conjunctivodacryocystorhinostomy (CDCR) procedures using a porous polyethylene (MEDPOR(R)) coated tear drain (MCTD(R)). METHODS: From 2002 to 2007, 120 patients who had been treated with endoscopic CDCR using MCTD(R) were investigated for its success rates and complications. After an osteotomy was made under nasal endoscopy, a tunnel was created from the caruncle in the conjunctival sac to the nasal cavity through the newly created ostium, and then the tunnel was enlarged to allow the insertion of the MCTD(R) The length of the tube to be inserted was determined under endoscopic examination. An anchoring suture was placed at the medial canthus to both the conjunctiva and the skin using a 5-0 Vicryl suture in the fashion of a purse string suture. RESULTS: Causes of obstruction included failed dacryocystorhinostomy (DCR) (74 cases) and idiopathic obstruction (22 cases). Postoperative complications were encountered in four cases with tube loss, 21 cases with a buried tube, 8 cases of extrusion to the conjunctival side, and 11 cases with obstruction caused by conjunctival incarceration or granuloma. The postoperative success rate was 89.1%. CONCLUSIONS: The authors concluded that endoscopic CDCR using MCTD(R) is an alternative to the standard conventional method for preventing dislodgement of the tube postoperatively. However, surgeons should consider that it may be challenging to insert the MCTD(R) and that in cases requiring removal, the tube can be difficult to remove due to adhesions.
Key Words: Conjunctivodacryocystorhinostomy;MCTD;Porous polyethylene coated tear drainage tube


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next