Clinical Outcomes of Diffractive Aspheric Trifocal Intraocular Lens Implantation.
Jung Hyun Lee, Young Joo Cho, Tae Hyung Lim, Kee Yong Choi, Beom Jin Cho
1Department of Ophthalmology, HanGil Eye Hospital, Incheon, Korea. chobjn@empas.com
2Department of Ophthalmology, Catholic Kwandong University College of Medicine, Gangneung, Korea.
회절 비구면 삼중초점 인공수정체 임상성적 및 시력의 질에 대한 설문조사
이정현1⋅조영주1⋅임태형1,2⋅최기용1⋅조범진1,2
한길안과병원 안과1, 가톨릭관동대학교 의과대학 안과학교실2
Correspondence:  Beom Jin Cho,
Email: chobjn@empas.com
Received: 24 August 2017   • Revised: 7 December 2017   • Accepted: 23 January 2018
Abstract
PURPOSE
To evaluate the clinical outcomes of patients with diffractive aspheric trifocal intraocular lens FineVision Pod F IOL (PhysIOL, Liège, Belgium) implantation. METHODS: Thirty eight eyes received phacoemulsification and implantation of FineVision Pod F IOL. Uncorrected distant visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), refractive values, and defocus curve were evaluated at postoperative 1 month and 3 months. Optical quality was evaluated with the contrast sensitivity test, OQAS® (Optical Quality Analysis System, Visiometrics, Cerdanyola del Vallès, Spain) and questionnaire. RESULTS: At the 3-month postoperative follow-up, the mean spherical equivalent was 0.01 ± 0.31 D and the mean UDVA, UIVA and UNVA were 0.04 ± 0.07, 0.19 ± 0.12, and 0.04 ± 0.07, respectively. Mean contrast sensitivities at 0.75, 1.5, 3, 6, 12, and 18 cycles per degrees were 2.00 ± 1.54, 2.16 ± 1.60, 2.25 ± 1.76, 2.16 ± 1.83, 1.52 ± 1.47 and 1.03 ± 0.95 respectively and mean objective scatter index by OQAS® (Optical Quality Analysis System, Visiometrics) was 1.54 ± 0.74. In satisfaction analysis, general satisfaction with surgery was 89% and spectacle independence were 89% at far, 78% at intermediate and 83% at near distance. Postoperative dissatisfaction factors were dryness (36%), glare at night (32%), halo (18%). CONCLUSIONS: The FineVision Pod F IOL showed excellent distant and near visual acuities with an effective intermediate visual acuity. The eyes with FineVision Pod F IOL expected to achieve the favorable visual outcome and patient satisfaction.
Key Words: Cataract;FineVision Pod F IOL;Intermediate visual acuity;Patient satisfaction;Trifocal IOL


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next