J Korean Ophthalmol Soc > Volume 53(8); 2012 > Article
Journal of the Korean Ophthalmological Society 2012;53(8):1076-1080.
DOI: https://doi.org/10.3341/jkos.2012.53.8.1076    Published online August 15, 2012.
Changes in Higher Order Aberration According to Tear-Film Instability Analyzed by Continuous Measurement Using Wavefront.
Si Hwan Choi, Yong Il Shin
Department of Ophthalmology, Chungnam National University School of Medicine, Daejeon, Korea. shchoi@cnu.ac.kr
웨이브프론트의 연속 측정방법으로 분석한 눈물막의 불안정성에 따른 고위수차 변화
최시환⋅신용일
Department of Ophthalmology, Chungnam National University School of Medicine, Daejeon, Korea
Abstract
PURPOSE
To evaluate the changes of higher order aberration according to tear-film instability measured serially by KR-1W wavefront every second for 10 seconds. The present study also analyzed the relationship between higher order aberration and the tear-film break-up time, Schirmer test, and superficial punctate keratitis. METHODS: The 228 eyes of 114 patients randomly selected from patients who visited hospital were measured once every second for 10 seconds after eye blinking by continuous measurement using wavefront. RESULTS: Higher order aberration increased overtime, and the higher order aberration value measured at the tenth second subtracted from the value of the first second was statistically significant (p = 0.004). In addition, the increment in higher order aberration between 9 seconds and 10 seconds was statistically significant (p = 0.01). The group of patients with a tear-film break-up time less than 6 seconds showed the greatest changes when measuring the higher order aberration difference value between the tenth and first seconds, which was statistically significant (p = 0.002). The group of patients where the Schirmer test results were longer than 10 millimeters and who had superficial punctate keratitis showed the greatest statistically significant changes when measuring the difference in higher order aberration values between the tenth and first seconds (p = 0.008, p = 0.005, respectively). CONCLUSIONS: Analysis of higher order aberration by wavefront could be useful in cases of decreased optical quality, diagnosis and evaluation of treatment in dry eye syndrome.
Key Words: Dry eye syndrome;Higher order aberration;KR-1W;Wavefront


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next